En esta ocasión voy a revelar el significado de los códigos de error de la copiadora ricoh mp 5001
Esta es mi contribución para mis seguidores de todo el mundo, y gracias por leer mis artículos, siempre tratando de entregar algo nuevo e interesante pero sobre todo algo que les sirva a todos los técnicos de copiadoras de la marca Ricoh,Hoy les doy los códigos error de estos modelos en ingles porque no quisiera deformar la información con algo mal traducido. ya que son copiadoras, de medio uso que apenas esta entrando al país en este caso es México.
códigos de error para solucionar fallas en la copiadora ricoh mp 5001 |
SC Tables: SC1xx
Exposure
lamp error
|
||
001: Shading at AGC
-002: Shading at scanning
The standard white level was not detected properly when scanning the white
plate
|
||
101
|
D
|
Exposure lamp defective
Lamp stabilizer defective
Exposure lamp connector defective
Standard white plate dirty
Scanner mirror or scanner lens out of position or dirty
SBU
defective
BICU
defective
|
The peak white level is less than 64/255 digits (8 bits) when scanning
the shading plate. (The shading data peak does not reach the specified threshold)
|
Scanner
home position error 1
|
||
120
|
D
|
The scanner home position sensor does not detect the "OFF"
condition during initialization or copying.
|
SIB (B/W), SIB (Color) or scanner drive motor defective
Scanner motor defective
Harness between SIB and scanner drive motor disconnected
Harness between SIB and scanner drive motor power source disconnected
Scanner HP sensor defective
Harness between SIB and HP sensor disconnected
Scanner wire, timing belt, pulley, or carriage defective
BICU
defective
|
Scanner
home position error 2
|
||
The scanner home position sensor does not detect the "ON"
condition during
initialization
or copying.
|
||
121
|
D
|
SIB (B/W), SIB (Color) or scanner motor drive board defective
Scanner motor defective
Harness between SIB and scanner drive motor disconnected
Harness between SIB and scanner drive motor power source disconnected
Scanner HP sensor defective
Harness between SIB and scanner HP sensor disconnected
Scanner wire, timing belt, pulley, or carriage defective
BICU
defective
|
Black level detection error (Color Scanner model
only)
|
||
141
|
D
|
The black level cannot be adjusted within the target value during the
zero clamp.
|
Defective SBU
BICU
defective
|
White level detection error (Color Scanner model
only)
|
||
142
|
D
|
The white level cannot be adjusted within the target
during auto gain control.
|
Dirty exposure glass or optics section
SBU board defective
Exposure lamp defective
Lamp
stabilizer defective
BICU
defective
|
.
SBU auto adjust error (B/W Scanner model only)
|
||
143
|
C
|
One of the following occurred:
When the machine was powered on, automatic adjustment of the SBU failed.
Automatic white density adjustment failed when reading standard white plate.
|
Exposure lamp defective
Lamp stabilizer defective
Lamp stabilizer connection loose, disconnected or damaged
White plate mounting is incorrect or defective
Scanner mirror or scanner lens out of position or dirty
SBU, SCNB defective
BICU defective
Harness connections
|
-001:
SBU connection error
|
|||
D
|
The SBU connection cannot be detected at power on or recovery from the
energy save mode.
|
Defective SBU
Defective harness
Defective detection port on the BICU
|
|
-002:
SBU serial communication error
|
|||
144
|
D
|
The power ON of the SBU is not detected.
|
Defective SIO, SBU or SCNB
Defective harness
Defective detection port on the BICU
|
-003:
GASBU reset error
|
|||
D
|
The serial communication does not work.
|
Defective SBU
Defective detection circuit on the BICU
Defective harness
|
|
-004:
VERSION error
|
|||
D
|
The serial communication does not work.
|
Defective SBU
Defective detection circuit on the BICU
Defective harness
|
Scanner adjustment error (B/W Scanner model only)
|
||
145
|
C
|
During the SBU adjustment, the machine detects that the white level
read from the white plate or paper is out of range. (SP4015)
|
Exposure lamp defective
Dirty white plate
Incorrect position or width of white plate scanning (SP4015)
BICU board defective
SBU board defective
|
BICU
error
|
||
161
|
D
|
The error result of self-diagnostic by the ASIC on
the BICU is detected.
|
Defective BICU
Defective connection between BICU and SBU
|
Copy Data Security Unit error
|
||
165
|
D
|
The copy data security board is not detected when the copy data
security function is set "ON" with the initial setting.
A device check error occurs when the copy data security function is
set to "ON" with the initial setting.
|
Incorrect installation of the copy data security board
Defective copy data security board
|
SC Tables: SC2xx
Polygon motor error 1: ON timeout
|
||
202
|
D
|
The polygon mirror motor does not reach the targeted operating speed
within 10 sec. after turning on or changing speed
|
Polygon motor error 2: OFF timeout
|
||
203
|
D
|
The polygon mirror motor does not leave the READY status within 3 sec.
after the polygon motor switched off.
|
Polygon
motor error 3: XSCRDY signal error
|
||
204
|
D
|
The SCRDY_N signal remains HIGH for 200 ms while the
LD unit is firing.
|
Polygon motor/driver board harness loose or broken
Polygon motor/driver board defective
Laser
optics unit defective
BICU
defective
|
Laser synchronizing detection error: start position
LD0
|
||
220
|
D
|
The laser synchronizing detection signal for the start position of the
LDB is not output for two seconds after LDB unit turns on while the polygon
motor is rotating normally
|
The Copy Data Security Unit card not installed
The Copy Data Security Unit card is installed, but it is not the
correct type for the machine.
|
Laser synchronizing detection error: start position
LD1
|
||
221
|
d
|
The laser synchronizing detection signal for the start position of the
LDB is not output for two seconds after LDB unit turns on while the polygon
motor is rotating normally.
|
The Copy Data Security Unit card not installed
The Copy Data Security Unit card is installed, but it is not the
correct type for the machine.
|
FGATE
ON error
|
||
230
|
D
|
The FGATE signal does not assert within the prescribed time. (The BICU
generates the FGATE signal and sends it to the LD unit when the registration sensor
switches on.)
|
FGATE
OFF error
|
||
231
|
D
|
The FGATE signal does not assert within the prescribed time. (The BICU
generates the FGATE signal and sends it to the LD unit when the registration sensor
switches on.)
|
BICU defective
BICU, Controller board harness loose or broken
Controller
board defective.
|
LD
error
|
||
240
|
C
|
The BICU detected a problem at the LD unit.
|
Worn-out LD
Disconnected or broken harness of the LD.
|
SC Tables: SC3xx
Charge
roller bias leak
|
||
302
|
D
|
A charge roller bias leak signal was detected.
|
Charge roller damaged
High voltage supply board defective
PCDU harness defective or disconnected
|
Charge roller bias correction leak
|
||
304
|
D
|
The charge roller bias correction is performed twice even if the
maximum charge roller bias (-2000V) is applied to the roller.
|
ID sensor defective
Worn charge roller
Charge
roller damaged
|
Development
roller bias leak
|
||
320
|
D
|
The development roller bias leak is detected for 60 ms after the high
voltage has been supplied to the development unit.
|
Development bias leak
Broken harness
Defective high voltage power supply, voltage supply
Defective high voltage supply unit
|
Development
paddle motor error
|
||
324
|
D
|
The machine detects a lock signal error from the development puddle
motor for 2 seconds after the drum motor has turned on.
|
Overload on the development puddle motor
Defective development puddle motor
Defective harness
Defective
IOB
|
ID sensor pattern test error
|
||
350
|
D
|
One of the following readings occurred 10 times in the ID sensor
output when the ID sensor pattern was checked:
1) Vsp > 2.5V
2) Vsg < 2.5V
3) Vsp =0V
4)
Vsg = 0V
|
ID sensor connector defective
Poor ID sensor connector connection
I/O board (IOB) defective
Poor writing of ID sensor pattern on the drum
High voltage supply board defective
|
ID sensor Vsg test error
|
||
351
|
D
|
When the ID sensor was checked, the ID sensor output voltage is 5.0V
while the LED current value is 0.
|
ID sensor defective or dirty
ID sensor connector defective
Poor ID sensor connection
I/O board (IOB) defective
Scanning system defective
High voltage supply board defective
Defect at the ID sensor pattern writing area of the drum
|
Grayscale
measurement error
|
||
355
|
C
|
When the grayscale control result is the maximum and it does not
operate correctly and these cases are detected 15 times.
|
ID sensor defective or dirty
The life of ID sensor or photo conductor
Shield
glass dirty
|
TD
sensor (Vt) error 1
|
||
360
|
D
|
The following condition occurs thirty times consecutively during
printing. Vt
is less than 0.5V or 4.8V or more
|
TD sensor disconnected
Harness between TD sensor and PCDU defective
Defective
TD sensor.
|
TD
sensor adjustment error
|
||
372
|
D
|
Vts is less than 1.8V or 4.8V or more during TD
sensor initialization.
|
Heat seal not removed from a new developer pack
TD harness sensor disconnected, loose or defective
TD sensor defective
Harness between TD sensor and drawer disconnected, defective
|
Drum
motor error
|
||
396
|
D
|
The machine detects a lock signal error from the drum motor for 2
seconds after the drum motor turned on.
|
Overload on the motor
Defective drum motor
Defective harness
Defective IOB
|
SC Tables: SC4xx
Vsg adjustment
error
|
||
400
|
D
|
Vsg is more than 4.2V or 3.8V or less when the
machine adjusts Vsg value.
|
Dirty or defective ID sensor
Defective ID sensor shutter
|
Transfer
belt bias error
|
||
440
|
D
|
The feed back bias from the transfer belt is more than 4V for 60 msec
while the transfer belt bias is output.
The A/D conversion level is 20 or less for 60 msec.
The PWM duty is 24% or more for 60 msec.
|
Power pack broken
Defective harness
Disconnected
connector
|
Transfer/Development
motor error
|
||
441
|
D
|
The machine detects a lock signal error from the transfer/development
motor
for 2 seconds after the transfer/development motor
turned on.
|
Overload on the motor
Defective transfer/development motor
Defective harness
Defective IOB
|
Transfer belt contact motor error
|
||
442
|
D
|
The transfer belt HP sensor detects incorrect movement of the transfer
belt after the transfer belt contact motor has turned on.
|
Dirty transfer belt HP sensor
Defective transfer belt contact motor
Disconnected connector of the transfer belt HP sensor or motor
Disconnected cable
Defective IOB
|
SC Tables: SC5xx
1st
tray lift malfunction
|
||
501
|
B
|
The tray lift sensor is not activated after the tray lift motor has
been on for 10 seconds. If the main power switch is turned on when the paper
is already at the feed height, the paper height position is detected again.
At this time, the tray lift sensor should de-activate within 1.5 sec after
the paper bottom plate starts to drop. If it does not deactivate within 1.5
sec., a message will prompt the user to reset Tray 1. After two attempts to
release the error by re-setting the paper tray, if this does not solve the
problem then this SC is displayed.
|
An obstruction (jammed paper, paper scraps, etc.) has blocked the motor
drive and caused an overload.
Tray lift sensor connection loose, disconnected, or damaged
Tray lift sensor defective
Tray lift motor connection loose, disconnected, or damaged
Tray lift motor defective
|
2nd
tray lift malfunction
|
||
502
|
B
|
The tray lift sensor is not activated after the tray lift motor has
been on for 10 seconds. If the main power switch is turned on when the paper
is already at the feed height, the paper height position is detected again.
At this time, the tray lift sensor should de-activate within 1.5 sec. after
the paper bottom plate starts to drop. If it does not deactivate within 1.5
sec., a message will prompt the user to reset Tray 2. After two attempts to re-set
the paper tray, if this does not solve the problem then this SC is displayed.
|
An obstruction (jammed paper, paper scraps, etc.) has blocked the motor
drive and caused an overload.
Tray lift sensor connection loose, disconnected, or damaged
Tray lift sensor defective
Tray lift motor connection loose, disconnected, or damaged
Tray lift motor defective
|
3rd tray lift malfunction (optional paper feed unit
or LCT)
|
||
-1
|
B
|
For the paper feed unit:
SC 503-01 occurs if the lift sensor does not turn on within 10 seconds
after the tray lift motor has turned on.
For the LCT:
SC 503-01 occurs if the lift sensor does not turn on or turn off
within 8 seconds after the tray lift motor has turned on to lift or lower the
tray.
|
For the paper feed unit:
Defective tray lift motor or connector disconnection
Defective lift sensor or connector disconnection
For the LCT:
Defective stack transport clutch or connector disconnection
Defective tray motor or connector disconnection
Defective end fence home position sensor or connector disconnection
Defective upper limit sensor or connector disconnection
Defective tray lift motor or connector disconnection
|
||
-2
|
B
|
This SC is generated if the following condition occurs 3 consecutive
times.
For the paper feed unit:
When the tray lowers, the tray lift sensor does not go off within 1.5
sec.
For the LCT:
When the main switch is turned on or when the LCT is set, if the end fence
is not in its position (home position sensor ON), the tray lift motor stops.
If the upper limit does not go off for 1.5 seconds even the tray lift
motor turns on to lower the tray after the upper limit has been detected at power
on.
|
For the paper feed unit:
Defective tray lift motor or connector disconnection
Defective lift sensor or connector disconnection
For the LCT:
Defective stack transport clutch or connector disconnection
Defective tray motor or connector disconnection
Defective end fence home position sensor or connector disconnection
|
504
|
4th tray lift malfunction (optional paper feed unit)
|
|
-1
|
B
|
For the paper feed unit:
When the tray lift motor turns on, the upper limit is not detected
within 10 seconds. If this condition occurs three consecutive times, the SC
is generated.
|
For the paper feed unit:
Defective tray lift motor or connector disconnection
Defective lift sensor or connector disconnection
|
||
-2
|
B
|
For the paper feed unit:
When the tray lift motor is turned on, the upper limit is not detected
within 10 seconds.
If this condition occurs three consecutive times,
the SC is generated.
|
Defective tray lift motor or connector disconnection
Defective lift sensor or connector disconnection
|
||
505
|
5th tray lift malfunction (optional LCT)
|
|
-1
|
B
|
This SC is generated if the following condition occurs:
When the tray lift sensor of the LCT 1200-sheet does not go on after
the tray lift motor has turned on to lift the paper tray.
When the tray lift sensor of the LCT 1200-sheet does not go off after
the tray lift motor has turned on to lower the paper tray.
When the tray lift sensor of the LCT 1200-sheet does not go on after
the pick-up roller solenoid has turned on at power on.
|
Tray lift motor defective or disconnected
Tray lift sensor defective or disconnected
|
||
-2
|
B
|
Both tray lift sensor and lower limit sensor are turned on at the same
time when the main power is turned on or the right door is closed.
|
Tray lift motor defective or disconnected
Tray lift sensor defective or disconnected
Lowe limit sensor defective or disconnected
|
Fusing exhaust fan motor error
|
||
530
|
D
|
The IOB does not receive the lock signal for10 seconds after turning
on the fusing exhaust fan.
|
Defective fusing exhaust fan motor or connector disconnection
Defective IOB
Disconnected harness
|
Exhaust
fan motor error
|
||
531
|
D
|
The IOB does not receive the lock signal for 10 seconds after turning
on the exhaust fan motor.
|
Defective exhaust fan motor or connector disconnection.
Defective IOB
Disconnected harness
|
Cooling
fan motor error
|
||
532
|
D
|
The machine does not detect the fan motor lock signal for 10 seconds
after turning on the cooling fan motor.
|
Defective cooling fan motor or connector disconnection.
Disconnected harness
Defective IOB
|
Paper
exit cooling fan motor error
|
||
533
|
D
|
The machine does not detect the fan motor lock signal for 10 seconds
after turning on the paper exit cooling fan motor.
|
Defective paper exit cooling fan motor or connector disconnection.
Defective IOB
Disconnected harness
|
Fusing
motor error
|
||
540
|
D
|
The IOB does not receive the lock signal for 2 seconds after turning
on the fusing motor.
|
Motor overload
Defective fusing motor or connector disconnection.
Defective IOB
Disconnected harness
|
Fusing
thermistor open (center)
|
||
541
|
A
|
The thermistor (center) detects 0°C or less for 5
sec.
|
Fusing thermistor disconnected
Fusing thermistor connector defective
|
Fusing temperature warm-up error(center)
|
||
542
|
A
|
This SC is generated if the following condition occurs:
The thermistor (center) does not detect an 8°C increment in the fusing
temperature for 7.5 sec. just after the fusing temperature reached 45°C.
The temperature of the center thermistor does not reach the target temperature
for 28 seconds after the fusing lamps turned on.
|
Thermistor
warped or broken
|
Fusing overheat error 1 (software detection)
|
||
543
|
A
|
A fusing temperature (at the center) of over 230°C (446°F) is detected
for 1 second by the fusing thermistors at the center or at either end of the
fusing roller.
|
Power supply unit defective
I/O board (IOB) defective
BICU defective
TRIAC short on PSU (PSU defective)
|
Fusing overheat error 1 (hardware detection)
|
||
544
|
A
|
A fusing temperature (at the center) over 250°C is detected by the
fusing temperature monitor circuit in the BICU board.
|
I/O board (IOB) defective
BICU
defective
|
Fusing lamp consecutive full power 1
|
||
545
|
A
|
After warm-up the fusing lamp remains at full power for 15 seconds
without the hot roller rotating.
|
desconnected or defective thermistors (center)
Defective
fusing lamp
|
Zero
cross error
|
||
547
|
D
|
The zero cross signal is detected three times even though the heater relay
is off when turning on the main power.
The zero cross signal is not detected for 2 seconds even though the heater
relay is on after turning on the main power or closing the front door.
The detection error occurs twice or more in the 11 zero cross signal detections.
This error is defined when the detected zero cross signal is less than 45.
|
Defective fusing lamp relay
Defective fusing lamp relay circuit
Unstable
power supply
|
Fusing
thermistor open (end)
|
||
551
|
A
|
The thermistor (end) detects 0°C or less for 5 sec.
|
Fusing thermistor (end) disconnected
Fusing thermistor (end) connector defective
|
Fusing temperature warm-up error (end)
|
||
552
|
A
|
This SC is generated if the following condition occurs:
The thermistor (end) does not detect an 8°C increment in the fusing temperature
for 7.5 sec. just after the fusing temperature reached 45°C.
The temperature of the end thermistor does not reach the target temperature
for 31 seconds after the fusing lamps turned on.
|
Thermistor warped or broken
|
Fusing overheat error 1 (software detection)
|
||
553
|
A
|
A fusing temperature (at the end) of over 230°C (446°F) is detected
for 1 second by the fusing thermistors at the center or at either end of the
fusing roller.
|
Power supply unit defective
I/O board (IOB) defective
BICU defective
TRIAC short on PSU (PSU defective)
|
Fusing overheat error 1 (hardware detection)
|
||
554
|
A
|
A fusing temperature (at the end) over 250°C is detected by the fusing
temperature monitor circuit in the BICU board.
|
I/O board (IOB) defective
BICU defective
|
Fusing lamp consecutive full power 1
|
||
555
|
A
|
After warm-up, the fusing lamp remains at full power for 15 seconds
without the hot roller rotating.
|
Disconnected or defective thermistors (ends)
Defective
fusing lamp
|
Zero
cross frequency error
|
||
557
|
C
|
When the zero cross signal is 66 or more and it is detected 10 times
or more in 11 detections, the machine determines that input 60 Hz and SC557 occurs.
|
Noise
(High frequency)
|
Fusing
unit jam
|
||
559
|
A
|
The fusing sensor detected a fusing unit paper late jam three times.
The paper was late and the fusing exit sensor could not detect the paper
three times.
|
Remove the paper that is stopped in the fusing unit.
Check that the fusing unit is clean and has no obstacles in the paper feed
path.
If the error persists, replace the fusing unit.
|
NOTA:
SC559 does not operate until SP1159 has been set to "1" (ON).
This sets the machine to count the number of occurrences of paper late jams in
the fusing unit. The default setting is "0" (OFF).
SC559 is issued after the third occurrence of a paper late jam in the
fusing unit. Once this SC has been issued, the machine cannot be used until the
service technician removes the cause of the jam and restores it to normal
operation.
The jam counter is reset after a sheet of paper successfully passes the
fusing exit sensor after the cause of the jam has been removed.
SC Tables: SC6xx
Mechanical
counter error: BK
|
||
610
|
D
|
This SC is only for NA models.
The machine detects the mechanical counter error when SP5987-001 is
set to "1".
|
Disconnected mechanical counter
Defective mechanical counter
|
Communication error between IOB and ADF
|
||
620
|
B
|
After the ARDF is detected, the break signal occurs or communication timeout
occurs.
|
Incorrect installation of ARDF
ARDF defective
IOB board defective
External noise
|
Communication timeout error between IOB and finisher
or mailbox
|
||
621
|
D
|
A break (low) signal is received from the finisher
or the mailbox.
|
Disconnected cable
Defective IOB
Defective main board in the peripherals
|
Paper feed unit communication error
|
||
622
|
D
|
While the IOB communicates with a peripheral, an SC code is displayed
if one of following conditions occurs.
The IOB receives the break signal which is generated by the peripheral
only just after the main switch is turned on.
The IOB receives the break signal which is generated by URAT.
|
Defective main control board of the peripheral
Defective BICU or IOB
Disconnected peripheral
|
2nd Paper Bank communication error
|
||
623
|
D
|
This SC is not issued for this machine.
When a communication error signal between the 1st paper bank and 2nd
paper bank is received.
|
Loose
connector
|
CSS
communication error
|
||
630
|
C
|
A communication error occurred during communication
with the CSS.
|
Communication
line error
|
MF
accounting device error 1
|
||
632
|
B
|
The controller sends data to the accounting device, but the device
does not respond. This occurs three times.
|
Loose connection between the controller and the accounting device
|
MF
accounting device error 2
|
||
633
|
B
|
After communication is established, the controller receives the brake
signal from the accounting device.
|
Loose connection between the controller and the accounting device
|
MF
accounting device error 3
|
||
634
|
B
|
The accounting device sends the controller the report that indicates a
backup RAM error has occurred.
|
Defective controller of the MF accounting device
Battery
error
|
MF
accounting device error 4
|
||
635
|
B
|
The accounting device sends the controller the report that indicates
the battery voltage error has occurred.
|
Defective controller of the MF accounting device
Battery
error
|
636
|
IC
Card Error
|
|
External
authentication module error
|
||
-01
|
D
|
This SC is generated if the external authentication is enabled and
following condition occurs:
No external authentication module
SD card error or external authentication module broken
No
DESS module
|
Version
error
|
||
-02
|
D
|
The version of the external authentication module is
not correct.
|
Incorrect
module versión
|
||
Management
area error
|
||
-99
|
D
|
The management number of the external authentication module exceeds the
maximum limit.
|
Software
error
|
BICU
communication error
|
||
641
|
D
|
The BICU does not respond to the frame transmitted
from the controller.
|
Defective controller
Detective BICU
|
650
|
Communication error of the remote service modem
(Embedded
RCG-M)
|
|
Authentication
error
|
||
-001
|
B
|
The authentication for the Embedded RCG-M fails at a
dial up connection.
|
Incorrect SP settings
Disconnected telephone line
Disconnected modem board
Check and set the correct user name (SP5816-156) and password (SP5816-157).
|
||
Incorrect
modem setting
|
||
-004
|
B
|
Dial up fails due to the incorrect modem setting.
|
Same as -001
Check and set the correct AT command (SP5816-160).
|
||
Communication
line error
|
||
-005
|
The supplied voltage is not sufficient due to a defective
communication line or defective connection.
|
|
Same as -001
Consult with the user's local telephone company.
|
||
Incorrect
network setting
|
||
-011
|
Both the NIC and Embedded RCG-M are activated at the
same time.
|
|
Same as -001
Disable the NIC with SP5985-1.
|
||
Modem board error
|
||
-012
|
The modem board does not work properly even though the setting of the modem
board is installed with a dial up connection.
|
|
Same as -001
1. Install the modem board.
2. Check and reset the modem board setting with SP5816.
3. Replace the
modem board.
|
Incorrect
dial up connection
|
||
-001:
Program parameter error
|
||
651
|
C
|
-002:
Program execution error
|
An unexpected error occurs when the modem (Embedded RCG-M) tries to call
the center with a dial up connection.
|
||
Caused by a software bug
|
EEPROM
error
|
||
669
|
D
|
Retry of EEPROM communication fails three times after the machine has detected
the EEPROM error.
|
Caused
by noise
|
Engine
startup error
|
||
670
|
D
|
The BICU fails to respond with the prescribed time when the machine is
turned on.
|
Connections between BICU and controller board are loose, disconnected,
or damaged
1. Replace the BICU
2. Replace the controller board
|
BICU
error
|
||
671
|
D
|
The model code from the BICU is not correct when the machine is turned
on.
|
Install the correct BICU for this model.
|
Controller-to-operation panel communication error at
startup
|
||
672
|
D
|
After the machine is powered on, the communication between the controller
and the operation panel is not established, or communication with controller
is interrupted after a normal startup.
After startup reset of the operation panel, the attention code or the attention
acknowledge code is not sent from the controller within 15 seconds.
After the controller issues a command to check the communication line with
the controller at 30-second intervals, the controller fails to respond twice.
|
Controller stalled
Controller board installed incorrectly
Controller board defective
Operation panel connector loose or defective
The controller is not completely shutdown when you turn the main switch
off.
Check the setting of SP5875-001. If the setting is set to "1
(OFF)", change it to "0 (ON)".
|
Memory address (PER) command error
|
||
687
|
D
|
The BICU does not receive a memory address command from the controller
for the prescribed time after the paper has reached the registration sensor.
|
Harness Disconnection at BICU
Controller board loose or broken
Defective BICU
Defective Controller Board
|
SC Tables: SC7xx
Original
stopper HP error
|
||
700
|
D
|
When the pick-up motor turns on clockwise, the original stopper HP
sensor does not detect the home position of the original stopper.
|
Defective original stopper HP sensor
Defective pick-up motor
Defective DF drive board
|
Pick-up roller HP error
|
||
701
|
D
|
When the pick-up motor turns on counterclockwise, the pick-up roller
HP sensor does not detect the home position of the pick-up roller.
|
Defective pick-up roller HP sensor
Defective pick-up motor
Defective DF drive board
|
Finisher
jogger motor error
|
||
721
|
B
|
The jogger fences move out of the home position but the HP sensor
output does not change within the specified number of pulses.
The 1st failure issues an original jam message, and the 2nd failure
issues this SC code.
|
Jogger HP sensor disconnected, defective
Jogger motor disconnected, defective
Jogger motor overloaded due to obstruction
Finisher main board and jogger motor
|
Stack feed-out motor error
|
||
723
|
B
|
The stack feed-out HP sensor does not detect the home position of the stack
feed-out belt 3000ms after the stack feed-out belt has moved to its home
position.
The stack feed-out HP sensor does not turn off 200 ms after the stack feed-out
belt has moved from its home position.
The 1st detection failure causes a jam error, and the 2nd failure
causes this SC code.
|
Defective stack feed-out HP sensor
Overload on the stack feed-out motor
Defective stack feed-out motor
Defective main board
Disconnected or defective harness
|
Finisher
exit guide plate motor error
|
||
725
|
B
|
After moving away from the guide plate position sensor, the exit guide
is not detected at the home position within the prescribed time.
The 1st detection failure issues a jam error, and the 2nd failure
issues this SC code.
|
Códigos de Error Copiadora Ricoh Mp 4001 y 5001 ( primera parte )
Reviewed by MARCELO CRISTOBAL PEREZ PLATA
on
1:18 p.m.
Rating:
Gracias ala empresa martec pues es una información invaluable este si es espíritu de servicio que dios los bendiga
ResponderBorrar